4600W Grid-tied Solar PV Inverterÿ4600TLMÿ4600TLM inverter High-yield?Max 97.6%efficiency?Real timeprecise MPPT algorithm for max harvest?Wide inputvoltage operation range from 100V to 550V?Two MPPtrackers for flexible PV panel configurationÿ4600TLM inverter Low maintenance cost?Rust-freealuminumcovers?Flexiblemonitoring solution?Multifunctionrelay can be configured to show various inverter informationÿ4600TLM inverter Flexible and economicalsystem solution?Free siteselection due to IP65?Easy installationand maintenance due to ?Plug & Play? connection?Interfaceselection-Wi-Fi/RS485/DryRelay for more flexible configuration and system monitoring?4? LCDdisplayÿÿ4600TLM inverter Intelligent grid management?Reactivepoweradjustable?Self powerreducerwhenover frequency?Remoteactive/reactivepower limit controlÿÿ4600TLM inverter datasheetTechnical DataSOFAR3000TLMSOFAR3680TLMSOFAR4000TLMSOFAR4600TLMSOFAR5000TLMInput (DC)Max. Input Power3100W3800W4160W4800W5200WMax. DC power for single MPPT2000(200V-500V)2400(200V-500V)2600(200V-500V)3000(200V-500V)Number of independent MPPT2Number of DC inputs1 for each MPPTMax. Input Voltage600VStart-up input voltage100V(+/-5V)Rated input voltage360VOperating input voltage range100V-550VMPPT voltage range160V-500V165V-500V175V-500VMax. Input current per MPPT10A/10A12A/12A13A/13A15A/15AInput short circuit current per MPPT12A14A16A18AOutput(AC)Rated power(@230V,50Hz)3000VA3680VA4000VA4600VA5000VAMax. AC power3000VA3680VA4000VA4600VA5000VANominal AC voltageL/N/PE, 220, 230, 240Nominal AC voltage range180V-270VGrid frequency range44~55Hz / 54~66HzActive power adjustable range0~100%Max. Output Current13A16A17.5A20A22ATHDi<3%Power Factor1(Adjustable +/-0.8)PerformanceMax efficiency97.6%Weighted eff.(EU/CEC)97.1%/97.3%Self-consumption at night<1WFeed-in start power20WMPPT efficiency>99.5%ProtectionDC reverse polarity protectionYesDC switchOptionalProtection class / overvoltage categoryI/IIIInput/output SPD(II)OptionalSafety ProtectionAnti-islanding, RCMU, Ground fault ÿmonitoringCertificationCE, CGC, AS4777, AS3100, VDE 4105, ÿC10-C11, G83/G59 (more available on request)CommunicationPower management unitAccording to certification and requestStandard Communication ModeWifi+RS485Operation Data Storage25 yearsGeneral dataAmbient temperature range-25? ~ +60?TopologyTransformerlessDegree of protectionIP65Allowable relative humidity range0 ~ 95% no condensingMax. Operating Altitude2000mNoise<25dBWeight18kgCoolingNatureDimension344?478?165mmWarranty5 yearsÿSolar panelsÿÿCertificationCNBM Solar strictly carries out the ISO 9001 quality control methodology and has implemented check points at every step of the production process to ensure our product performance durability and safety. The stringent quality control process has been confirmed by numerous independent agencies and LDK Solar modules earned IEC, TUV and UL certifications.úÿÿÿÿÿÿÿÿÿIEC:IECÿ61215, IEC 61730 (1&2), conformity to CEúÿÿÿÿÿÿÿÿÿUL 1703 2002/03/15 Ed:3ÿRev:2004/06/30úÿÿÿÿÿÿÿÿÿULC/ORD-C1703-01 Second Edition 2001/01/01úÿÿÿÿÿÿÿÿÿUL and Canadian Standard for Safety Flat-PlateúÿÿÿÿÿÿÿÿÿISO 9001: 2008 Quality Management SystemsúÿÿÿÿÿÿÿÿÿCEC Listed: Modules are eligible for California RebatesúÿÿÿÿÿÿÿÿÿPV Cycle: Voluntary module take back and recycling programúÿÿÿÿÿÿÿÿÿMCS CertificateÿÿFAQ1.ÿÿÿHow do I decide which system is right for me ?For protection from long outages, include a generator or solar panels in your Must solar system. Shorter outages can be handled by a battery-only system.2.ÿÿÿ Where my system will be installed ?Must solar systems are usually wall-mounted near a home's main electrical (circuit breaker) panel.3. How do I install my system ?A solar backup inverter is connected to a home electric system , we will supply detailed installation manual and videos for our customers .
We believe in the power of renewable energy to create a more sustainable future.
Copyright © 2024. All rights reserved.